Die Präsentation wird geladen. Bitte warten

Die Präsentation wird geladen. Bitte warten

1 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) First study1999:

Ähnliche Präsentationen


Präsentation zum Thema: "1 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) First study1999:"—  Präsentation transkript:

1 1 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) First study1999: J. H. Ficker, F. S. Fuchs, G. H. Wiest, G. Asshoff, G. Lehnert und E. G. Hahn First device with FOT: 2001 (SOMNOsmart) Successor:2004 (SOMNOsmart2) Weinmann has been the first manufacturer, who launched FOT with an APAP device successful. Weinmann´s philosophy: An effective APAP device must be able to distinguish between obstructive and central events, to prevent unnecessary pressure rise. To do not induce central apneas and the device should only apply the therapeutically needed pressure. Info to competition: ResMed and Philips Respironics started with their current device platform (S9, PR system ONE) the possibility to distinguish between open and closed airways. prismaLINE – Feature FOT

2 2 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) The oscillation is generated by the blower/turbine during the apnea. (In SOMNOsmart2: extra oscillation pump) Oscillation frequency: 4Hz (4 pulsations per second) Amplitude of pulsation:±0,2hPa Masks: Nasal- and Full Face prismaLINE – Feature FOT

3 3 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) Detection of closed upper airways: The FOT- signal applies pressure fluctuations, but as a result no flow is present. Thus, the upper respiratory tract is closed. prismaLINE – Feature FOT

4 4 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) Open airways? The FOT- signal applies pressure fluctuations, but as a result flow is present. Thus, the upper respiratory tract is open. prismaLINE – Feature FOT

5 5 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) FOT is active in prismaLINE, if no backup- frequency is activated: Devices with FOT: prismaLABin fixed BiLevel, with deactivated backup frequency (= prisma25S) prismaCRactive during softSTART- phase Exception: during initialization- period of 4min prisma20A FOT active / Exception: during initialization- period of 2min prisma25S FOT active prisma25ST FOT active in softSTART- phase prismaLINE – Feature FOT

6 6 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) Example: prismaCR and FOT in softSTART- phase + timed breaths under normal therapy prismaLINE – Feature FOT


Herunterladen ppt "1 Nur für internen Gebrauch © WEINMANN GERÄTE FÜR MEDIZIN GMBH+CO.KG  FOT (Forced Oscillation Technique) = OPS (Oscillating Pressure Signal) First study1999:"

Ähnliche Präsentationen