1 für-menschen-leben Competetor Devices for corpulsCPR Devices you might see in the field For internal use only! March 2012 Michael Heller

2 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbH für-menschen-leben LUCAS I and LUCAS II  Invented by JoLife in Sweden  At first distributed by Physio Control  JoLife has been bought by Physio Control in 2011 March 2012Competetor Devices for corpuls CPR 2 There are mainly two devices that are sold currently ZOLL Autopulse  Invented by Autopulse in the US  Zoll bought Autopulse and is the only distributor

3 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbH LUCAS I LUCAS II March 2012Competetor Devices for corpuls CPR 3 LUCAS I and LUCAS II powered by compressed airpowered by electricity (battery/mains)

4 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbH LUCAS I LUCAS II March 2012Competetor Devices for corpuls CPR 4 Compression Frequency: 100 compressions per minute Compression Depth: 5 cm (2 inches) Compression/Decompression Duty Cycle: 50% Sternum height 19 – 30.3 cm Maximum sternum width of 45 cm The use of LUCAS is not restricted by patient weight Height/with/depth: 65/33/25 cm Air hose lengths 3.3 meters Weight 6.3kg (unit) kg (supply) Compression Frequency: 100 ± 5 compressions per minute Compression Depth: 4-5cm Compression/Decompression Duty Cycle: 50 ± 5% Sternum height of 17 – 30.3 cm Maximum chest width: 45 cm The use of LUCAS is not restricted by patient weight Height/with/depth: 65/33/25 cm Weight 7.8kg (including battery) Facts about LUCAS I and II

5 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbH LUCAS I LUCAS II March 2012Competetor Devices for corpuls CPR 5 Operation: Fully pneumatic (compressed air) Breathing air from portable compressed air cylinder Air outlet in hospital/ambulance with nominal supply pressure within 46–87 psi (3.17– 6 bar) Air Consumption: 1.84 ft 3 per minute (52 L/minute) Operating Temperature: 5° C to 40°C Storage Temperature: -30° C to 60°C Operation: Battery - Rechargeable Lithium-Ion Polymer (LiPo) Size: 13.0 x 8.8 x 5.7 cm, Weight: 0.6 kg Battery voltage: 25.9 V Capacity: 3300 mAh (typical), 86 Wh Run time: 45 minutes (typical) Maximum battery charge time: Less than 4 hours at room temperature 22°C Recommendation to replace battery:  every 3 years or after 200 uses Operating temperature: 0°C to +40°C Charge temperature: 5°C to +35°C Facts about LUCAS I and II

6 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 6 Controls LUCAS II 2 preconfigured modes: 30:2 and continuous operation 3 LEDs for runtime indication No display or explanation of different alarms

7 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 7 Impressions of LUCAS

8 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 8 Impressions of LUCAS

9 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 9 Impressions of LUCAS

10 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 10 AutoPulse 100

11 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 11 Compression rate 80 ± 5 compressions per minute Equal to 20% reduction in anterior-posterior chest depth Physiological duty cycle 50 ± 5% Compression modes (user selectable):  30:2 (30 compressions with two 1.5 second ventilation pauses)  15:2 (15 compressions with two 1.5 second ventilation pauses) Continuous compressions Size (LxWxH): 82.6 cm by 44.7 cm by 7.6 cm Weight (excluding AutoPulse Battery): 9.3 kg Display Dot matrix LCD, actively backlit, adjustable contrast Operating temperature 0º to +40ºC Storage temperature 20º to +65ºC IP 24 Facts about AutoPulse 100

12 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 12 Type: Rechargeable Nickel-Metal Hydride (NiMH) Battery voltage (nominal): 32.4V Capacity: 3200 mAh (typical) Initial Battery runtime (nominal patient): 30 minutes (typical) Weight: 2.3 kg Size (L×W×H): 29.2 cm by 8.1 cm by 5.7 cm Maximum Battery charge time: Less than 4 1/4 hours at 25ºC (77ºF) Required replacement interval 100 full charge/discharge cycles Note: The Battery will not operate after 100 full charge/discharge cycles Operating temperature 0º C to +45ºC ambient, installed in device Charge temperature (5º C to +35ºC) ambient [20º C to 25ºC] preferred Facts about AutoPulse Battery

13 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 13 Video of the AutoPulse in use

14 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 14 Michigan Instruments „Thumper“

15 für-menschen-leben ©2012 GS Elektromedizinische Geräte G. Stemple GmbHMarch 2012Competetor Devices for corpuls CPR 15 AAT Animax

16 für-menschen-leben Competetor Devices for corpulsCPR / Version 1.0 English - for internal use only - Michael Heller Project Manager Research/Development GS Elektromedizinische Geräte G. Stemple GmbH Hauswiesenstraße Kaufering Germany Tel Fax